Skip to content

    Under active development. New calculators and features ship every week. Everything currently runs free while the site matures — pricing pages are a preview, checkout is not open yet.

    Calculates locally in your browser · fillet weld strength
    Structural / welding

    Fillet weld strength

    A fillet weld carries load on its throat, not its leg: the throat is 0.707 times the leg, and the nominal strength is 0.60 FEXX on that area. The plate it is attached to has to be checked separately, because a thin plate tears before a well-sized weld fails.

    GovernsWeld metalSize checkWithin rangeMin size0.188 in
    Design strength
    55.7 kip
    φ = 0.75 on 74.2 kip nominal
    Utilisation
    72%
    40.0 kip applied
    Throat
    0.1767 in
    0.707 × 0.250 in leg
    Length required
    7.18 in
    for 40.0 kip at this leg
    Weld and base-metal check
    The weld is sized on its throat; the plate is checked separately, because a thin plate fails before the weld does.
    56 kip
    Weld and base-metal check
    QuantityValueNote
    Fillet leg0.250 in4.0/16 in
    Effective throat0.1767 in0.707 × leg
    Effective length10.00 in
    ElectrodeE70FEXX = 70 ksi
    Weld nominal strength74.2 kip0.60 FEXX × throat × length
    Base-metal nominal174.0 kip0.60 × 58 ksi × 0.500 in × length
    Governing nominal74.2 kipweld metal controls
    Design strength55.7 kip0.75 × nominal
    Applied load40.0 kip
    Utilisation72%within capacity
    Minimum size0.188 inAISC Table J2.4 by thinner part
    Maximum size0.438 inAISC J2.2b along an edge
    Required length7.18 inat this leg size

    The minimum size exists to prevent cracking from rapid cooling on thick plate; the maximum exists because a weld larger than the plate edge cannot develop its full throat. Both are code requirements, not rules of thumb.

    Inspect the model
    Choose a quick result view, a scaled comparison, or the complete diagnostic set.
    Capacity against leg size
    Linear in the leg, because the throat is proportional to it.
    Capacity against leg size0.00026.2852.5678.84105.12131.4027.842/162/1641.763/163/1655.684/164/1669.605/165/1683.516/166/1697.437/167/16111.358/168/16kip
    Capacity against weld length
    Linear in length — the cheapest way to add capacity is usually more length, not a bigger leg.
    Capacity against weld length0.00024.9449.8974.8399.77124.71224466881010121216162020kip
    Canonical equations
    The exact relationships implemented by this engine.

    t_e = 0.707 w · For a 45° fillet.

    Rn = 0.60 FEXX · t_e · l · AISC J2.4.

    Rn = 0.60 Fu · t · l · Checked separately.

    φRn or Rn/Ω · φ = 0.75 LRFD, Ω = 2.0 ASD.

    engineering methodology

    A clear path from inputs to results.

    A fillet weld carries load on its throat, not its leg: the throat is 0.707 times the leg, and the nominal strength is 0.60 FEXX on that area. The plate it is attached to has to be checked separately, because a thin plate tears before a well-sized weld fails.

    Step-by-step methodWorked exampleAssumptions explained

    How to use

    1. Enter the fillet leg and the weld length.
    2. Choose the electrode and the base-metal tensile strength.
    3. Add the thickness of the thinner connected part.
    4. Read the design strength, which of the two limits governs, and the length required.

    The formula

    Rn=0.60 FEXX  (0.707 w)  lR_n = 0.60\,F_{EXX}\,\,(0.707\,w)\,\,l

    Reference: AISC 360 §J2.4 for fillet weld strength, Table J2.4 for minimum size and §J2.2b for maximum size.

    Worked example

    1/4 inch fillet, 10 inches long, E70 on A36 plate

    Inputs
    • 1/4 inch fillet leg, 10 inches of effective length.
    • E70 electrode on A36 plate (Fu = 58 ksi).
    • 1/2 inch plate, 40 kip applied load, LRFD.
    Calculation path
    1. 1

      The effective throat is 0.707 × 0.25 = 0.1767 in.

    2. 2

      Weld nominal strength is 0.60 × 70 × 0.1767 × 10 = 74.2 kip.

    3. 3

      Base-metal nominal strength is 0.60 × 58 × 0.5 × 10 = 174.0 kip, so the weld governs.

    4. 4

      The design strength is 0.75 × 74.2 = 55.7 kip.

    5. 5

      The 40 kip load uses 72% of it.

    6. 6

      At this leg the weld would need 7.18 in of length to carry the load, so 10 in is comfortable.

    Result

    55.7 kip design strength · 72% utilised · weld metal governs.

    Interpreting the result

    Which limit governs is a property of the plate, not the weld. A 1/4 inch fillet on 1/2 inch plate is weld-controlled; the same fillet on 1/4 inch plate is base-metal-controlled, and adding weld does nothing. The minimum and maximum size rules then bound the leg from both sides, so on thin plate there is sometimes no legal fillet at all.

    Assumptions & limitations

    • The weld is a 45° fillet loaded in shear through its throat.
    • The effective length excludes any end return or crater.
    • The base-metal check uses the thinner connected part and a uniform stress distribution.
    • Block shear, prying and the Whitmore section are not modelled.
    • Weld metal toughness, hydrogen control and preheat are material requirements outside this calculation.

    Frequently asked questions

    Why 0.707 times the leg?

    Because the throat of a 45° fillet is the perpendicular distance from the root to the face, which is the leg times cos 45°, or 0.707. The leg is what you measure; the throat is what carries the load.

    Why is there a maximum size?

    Along an edge thinner than 1/4 inch the weld cannot exceed the plate thickness, and on thicker plate it is limited to the thickness minus 1/16 inch. A weld bigger than the edge cannot develop its full throat and just wastes metal.

    Does weld length have a limit?

    Yes. AISC requires a fillet weld to be at least four times its leg in length, and end-loaded welds longer than 100 times the leg are subject to a reduction for non-uniform stress distribution.

    What is the minimum fillet size for?

    It prevents cracking from rapid cooling on thick plate. A small weld on a thick plate cools too fast and can crack, so Table J2.4 sets a minimum leg that increases with the thickness of the thinner part.

    When does the base metal govern?

    When the plate is thin relative to the weld. The base-metal strength scales with plate thickness, so a 1/4 inch fillet on 1/4 inch plate is limited by the plate — and making the weld bigger changes nothing.

    Methodology last reviewed 2026-10-21. Results are informational and not financial or engineering advice — see our disclaimer.